The Fluke 113 Digital Multimeter makes basic meter setup and reconnection testing quick and easy.
This easy-to-use meter has the features you need to solve most electrical problems.
The VCHEK LoZ low-impedance measurement function tests for voltage and continuity.
The LoZ low-impedance measurement function also blocks ghost voltages generated by adjacent conductors. *LoZ low-impedance measurements can trip an RCD by applying a low current to its protection circuit.
The Min/Max function allows you to record signal fluctuations.
The Fluke 113 can perform diode tests and also has auto and manual ranging.
Compliant with the latest safety standards, a backlight, and a large, easy-to-read display make this meter an essential addition to your toolbox.
□ Key Features □
- Test voltage and continuity with the VCHEK LoZ low-impedance measurement function*
- Accurately measure AC across nonlinear loads with True RMS
- Large, backlit display for easy viewing in low-light conditions
- Record signal fluctuations with the Min/Max function
- Diode tester for testing general-purpose germanium, silicon, and power diodes
- Integrated holster with probe holder for easy storage
- Enhanced user functionality with automatic and manual ranging
- Higher levels of safety with CAT III 600 V and CAT IV 300 V measurement category compliance
- Optional TPAK magnetic hanger for hands-free operation
□ Specifications □
[VCHEK] *1, 2, 3
Range/Resolution: 6.000 V/0.001 V
Range/Resolution: 60.00 V/0.01 V
Range/Resolution: 600.00 V/0.1 V
Accuracy: DC, 45 ~ 500Hz: 2.0% + 3 | 500Hz ~ 1kHz: 4.0% + 3
[Diode Test] *4
Range: 2.000V
Resolution: 0.001V
Accuracy: 2.0% + 3
[Continuity] *4 Beeper on for <20Ω, off for >250Ω. Detects opens or shorts lasting 500μs or longer. [Resistance *4]
Range/Resolution: 600.0Ω/0.1Ω | Accuracy: 0.9% + 2
Range/Resolution: 6.000kΩ/0.001kΩ | Accuracy: 0.9% + 1
Range/Resolution: 60.00kΩ/0.01kΩ | Accuracy: 0.9% + 1
[Capacitance *4]
Range/Resolution: 1000nF/1nF | Accuracy: 1.9% + 2
Range/Resolution: 10.00μF/0.01μF | Accuracy: 1.9% + 2
Range/Resolution: 100.0μF/0.1μF | Accuracy: 1.9% + 2
Range/Resolution: 100~1000μF/1μF | Accuracy: 1.9% + 2
Range/Resolution: 1000μF or greater / 1μF | Accuracy: 5% + 20
Notes:
*1. All VCheck voltage ranges are specified from 60 counts to 100% of range. Inputs below 60 counts are not specified, so it is possible and common for a Fluke 113 or other true-rms meter to display a non-zero reading if the test leads are disconnected from the circuit or shorted together.
*2. Crest factor ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
*3. The minimum input voltage measurable with VCHECK autoranging is 3V DC. For measurements below 3V DC, press the [Range] button twice to manually range to 6V DC.
4. After measuring voltage, wait one minute to maintain accuracy for resistance, capacitance, diode test, and continuity.
□ Mechanical/General Specifications□
[Maximum Voltage Between Any Terminal and Ground] 600 V
[Display] 3 3/4 digits, 6,000 counts, updated four times per second
[Operating Temperature] -10°C to 50°C
[Battery Type] 9V Alkaline (ANSI 1604A/IEC 6F22)
[Battery Life] Alkaline: Typically 300 hours without backlight
[Dimensions] 167 x 85 x 46 mm
[Weight] 404g
[Warranty] 3 years
The VCHEK LoZ low-impedance measurement function allows you to test voltage and continuity. The LoZ low-impedance measurement function also blocks ghost voltages caused by adjacent conductors. *LoZ low-impedance measurements may trip the RCD by applying a low current to the RCD's protection circuit.
True RMS for accurate AC measurements on non-linear loads. Measurement functions: voltage, continuity, resistance, capacitance, diode test.